# What Thermal Imaging Finds in a Home Inspection (and What It Can’t)

- Link: https://propertyinspectionsplus.com/thermal-imaging-home-inspection-what-it-finds/
- Published: 2026-10-30T15:00:00+00:00
- Author: homeinspectordan

A thermal camera shows me temperature differences on the surface of a wall, ceiling
or floor. That’s how I find wet drywall, missing insulation, AC registers that aren’t
cooling and electrical parts running hot, none of which you can see with your eyes.
What it can’t do is look through the wall, prove a cool spot is water, or catch 
a leak that hasn’t started yet.

So it’s a great tool. It’s not X-ray vision. Here’s what it actually finds in Arizona
homes, where it falls short, and what to do when your report has a thermal image
in it.

## What a thermal camera actually sees

The camera reads heat coming off a surface and turns it into a picture. Warm shows
up one color, cool shows up another. That’s it. InterNACHI’s guide for inspectors
puts it simply: [“Thermal images show surface-heat variations.”](https://www.nachi.org/ir-camera-overview-inspectors.htm)
The camera doesn’t know why a spot is cooler. It just tells me where to look.

Water is the big one. Wet drywall cools off as the water evaporates, so a wet spot
reads cooler than the dry wall around it. InterNACHI’s moisture guide explains that
wet areas show up as [dark areas in the thermal image](https://www.nachi.org/ir-cameras-inspecting-moisture.htm),
and the camera is picking up the temperature difference, not the water itself.

Arizona actually helps here. The camera works best when there’s a big temperature
difference between inside and outside. InterNACHI’s guide to [inspecting for air leaks with IR cameras](https://www.nachi.org/ir-cameras-inspection.htm)
calls a 15 to 20 degree difference ideal, and says the peak of the cooling season
is a good time to scan because the air conditioning can be run to widen the gap.
On a summer afternoon in the Valley, with the sun on the stucco and the AC holding
the house cool, problems jump right out on the screen.

## What it finds in Arizona homes

These are the things I use the camera for on almost every house:

 * **Wet drywall and ceilings.** Under bathrooms, around tubs and showers, below
   upstairs sinks, and on garage ceilings under a second-floor bathroom. On a 1997
   Glendale home, the camera confirmed [active leaks from an upstairs bathroom](https://propertyinspectionsplus.com/glendale-home-hidden-moisture-thermal-imaging/)
   that were already showing in the garage ceiling below.
 * **Missing insulation.** Warm patches on the ceiling where the insulation has 
   been pushed aside or was never installed. InterNACHI notes these hot and cold
   spots can point to missing or inadequate insulation, which then gets checked 
   up close.
 * **AC registers that aren’t cooling.** I run the air conditioning and scan every
   register. On a rebuilt 1969 house, most registers were putting out 57 to 61 degree
   air, but a handful in the hallway and a bedroom were at 80 to 85. That points
   to a duct problem in the attic.
 * **Hot electrical parts.** Breakers, wires and outlets that are running warmer
   than everything around them. Heat in electrical is a fire chain, so that one 
   goes straight to an electrician.
 * **Roof leaks.** A roof leak that has soaked the ceiling shows up the same way
   wet drywall does, so I scan the ceilings closely, especially after a monsoon 
   storm.

## What it can’t do

This is where people get the wrong idea. A thermal camera is a lead, not a verdict.

 * **It can’t see through walls.** It reads the surface. If a pipe is dripping inside
   the wall cavity but the drywall hasn’t cooled off yet, there may be nothing to
   see.
 * **A cool spot isn’t always water.** It can be missing insulation, an AC register
   nearby, or a draft. That’s why I don’t write “leak” off the camera alone.
 * **Shiny surfaces fool it.** InterNACHI warns that reflective surfaces can pick
   up heat from something else in the room, like [“a hot light bulb elsewhere in the room.”](https://www.nachi.org/ir-camera-overview-inspectors.htm)
   Tile, glass and metal need a second look from another angle.
 * **It shows today, not next week.** If a fitting is fine during the inspection
   and starts dripping three days later, no camera is going to catch that ahead 
   of time.
 * **It can’t see what I can’t reach.** On that rebuilt 1969 house, the builder 
   never put in an attic access. The camera told me several ducts weren’t cooling,
   but with no way into the attic I couldn’t see why.

## A leak that showed up after the inspection

The video above is a good example of that last point. I inspected a vacant house
in San Tan Valley, and a few days later my client called and said the toilet in 
the bathroom was leaking. So I drove back out, got the door opened through the showing
service, and found water all the way around the base of the toilet, actively dripping.

Here’s the catch. The leak wasn’t at the shutoff valve itself. It was at the compression
fitting on the back side of the angle stop, where the copper pipe connects. So turning
the angle stop off did nothing, because the water was getting out before it ever
reached the valve. I had to shut off the main water to the house and drain the toilet
tank to stop it.

The report had already called out peeling paint and water lines in that spot, so
this wasn’t a brand-new leak. But it wasn’t that visible on inspection day. Sitting
vacant, with water in the lines and nobody checking, it got a lot worse in a few
days. Left alone, water like that gets under the flooring and starts warping it 
up.

The good news: it’s not the end of the world. A new angle stop on a compression 
fitting is not a difficult fix. A handyman or a plumber can do it. The lesson is
that a thermal scan, a moisture reading or any inspection is a snapshot of one day.
Your final walkthrough matters, and so does calling your inspector if something 
changes.

## How I confirm what the camera shows

When the camera shows me a cool spot, I put a moisture meter on it before it goes
in the report. InterNACHI’s guidance is the same: [“thermal imaging should be used in conjunction with a moisture meter.”](https://www.nachi.org/ir-cameras-inspecting-moisture.htm)
The camera finds it fast. The meter tells me if it’s actually wet.

I also run water. Showers, tubs and sinks get used during the inspection, and then
I scan the walls and ceilings around and below them. A drip that only happens when
water is flowing won’t show up on a dry wall. Same thing with the AC: I let it run
before I scan the registers, so I’m reading real airflow and not just a warm house.

For electrical, a hot spot at the panel gets written up for an electrician. The 
Electrical Safety Foundation lists [electrical warning signs](https://www.esfi.org/electrical-warning-signs-video-short/)
like warm outlets, a burning smell, discolored switches and lights that flicker 
or dim, and says to have a qualified electrician check the home. I’m not going to
diagnose the circuit. I’m going to tell you it’s hot and who to call.

## What to do if your report has a thermal finding

 * **Find the spot.** The thermal images are in your report. Go look at that wall
   or ceiling yourself so you know exactly where it is.
 * **Wet area confirmed:** get a licensed plumber out for an estimate to find the
   source. If it’s under a roof, call a roofer. If the area has been wet a long 
   time, ask about [air quality testing](https://propertyinspectionsplus.com/mold-air-quality-testing/).
 * **Cooling problem at the registers:** an HVAC tech for an estimate on the ductwork
   in the attic.
 * **Hot breaker or outlet:** a licensed electrician, before you close.
 * **Put it on the BINSR.** Leaks and electrical heat are the kind of items buyers
   ask the seller to address. Here’s [how the BINSR works in Arizona](https://propertyinspectionsplus.com/binsr-arizona-home-inspection-repair-request/).
 * **Check it again at the walkthrough.** Look under sinks and around toilets, and
   look at the water meter with everything off. If something changed since the inspection,
   call me.

## Thermal imaging inspections in Gilbert and across Arizona

I scan homes with a thermal camera as part of my [residential home inspections](https://propertyinspectionsplus.com/residential-home-inspection/),
and you can read more about how it works on my [thermal imaging inspection](https://propertyinspectionsplus.com/thermal-imaging-inspection/)
page. I inspect homes in [San Tan Valley](https://propertyinspectionsplus.com/home-inspector-san-tan-valley-az/),
[Queen Creek](https://propertyinspectionsplus.com/home-inspector-queen-creek-az/)
and the rest of the Valley. Every home inspection includes a [termite (WDO) inspection](https://propertyinspectionsplus.com/termite-inspection/)
at no extra charge, plus a 1-year termite warranty through [Firehouse Pest Control in Gilbert](https://firehousepest.com/services/termite-treatment/)
if no active termites are found.

**Buying a home?** [Book your inspection online](https://app.spectora.com/home-inspectors/my-inspection-company-f8d6dbae4e/schedule)
or call [623-399-0079](https://propertyinspectionsplus.com/thermal-imaging-home-inspection-what-it-finds/6233990079).

Property Inspections Plus is a [Gilbert, AZ home inspection](https://propertyinspectionsplus.com/)
company led by Certified Master Inspector Dan Pierce. We inspect homes across the
East Valley, the Phoenix metro and the rest of Arizona. See all of our [service areas](https://propertyinspectionsplus.com/service-areas/).