If you are buying a manufactured home in Arizona, there is a good chance the furnace says Intertherm or Miller. Frigidaire, Maytag, Gibson, Tappan, Westinghouse and Broan central air and heating equipment come from the same company, long known as Nordyne and later Nortek Global HVAC. Here is how to read the age and what each era means.
Who makes what
- Intertherm and Miller. The company started in St. Louis in 1919 as International Oil Heating, became Intertherm in 1969, and built heating and air conditioning for manufactured housing for decades.
- Nordyne. Nortek bought Intertherm in 1985, and it became Nordyne in 1987.
- Frigidaire, Tappan, Gibson, Philco and Kelvinator. From 1998 Nordyne sold central heating and cooling under these Electrolux names, and it built Maytag-brand units under license. These are not the same companies that make the kitchen appliances.
- Nortek Global HVAC. The name since 2015 (relaunched as NGH in 2022). Rheem bought NGH in October 2024.
Source: the Building Center’s Nordyne page.
How to read the serial number
On a manufactured home furnace, the data plate is usually inside the furnace door. On an outdoor AC or heat pump, it is on a side panel.
| Layout | Example | How to read it |
|---|---|---|
| Three letters, then numbers (most units) | GBB030708229 | Skip the three letters. The next two digits are the year and the two after that are the month: 03 = 2003, 07 = July. Dashes are sometimes added, as in GBB-0307-08229. |
| A letter in the middle | MN3D102 F3891 4228 | This is a Rheem-style serial, likely a unit built by Rheem. The four digits after the middle letter are the week and year: week 38 of 1991. |
If the serial does not fit either pattern, look for a date printed on the plate or call the brand’s support line with the serial number.
AC eras every Arizona buyer should know
These federal rules apply to every brand, so the build date tells you a lot about what is inside the unit.
| When | What changed | What it means for you |
|---|---|---|
| 1992 | First federal efficiency minimum: 10 SEER for split systems | A unit this old is long past its life in our heat. |
| January 23, 2006 | The minimum rose to 13 SEER. | Newer units use noticeably less power. |
| January 1, 2010 | New AC equipment could no longer be built to use R-22. | An R-22 unit was made before 2010. |
| January 1, 2015 | Split ACs installed in Arizona had to reach 14 SEER, plus an EER minimum for hot weather. | Arizona is in the Department of Energy’s Southwest region, with the toughest rules. |
| January 1, 2020 | R-22 production ended. | Recharging an R-22 system relies on recycled refrigerant and is expensive. Budget for replacement. |
| January 1, 2023 | A new test (SEER2). Southwest split ACs under 45,000 BTU must reach 14.3 SEER2 plus an EER2 minimum. | Labels from 2023 on show SEER2 numbers, which run a bit lower than the old SEER. |
| January 1, 2025 | New home systems can no longer be built for R-410A. Most now use R-454B or R-32. | R-410A units built before 2025 can still be installed and serviced. Ask what refrigerant a “new” unit uses. |
Sources: the Department of Energy’s central air conditioner standards FAQ and the EPA’s pages on the R-22 phaseout and refrigerant transition.
Model numbers
These brands use many prefixes, so focus on the size code. In a model such as JS4BD-036K, the 036 means 36,000 BTU, or 3 tons. On a manufactured home furnace, the data plate also says whether it is gas or electric and whether it is approved for manufactured housing, which matters for any replacement.
What to know in a manufactured home
- Use the right replacement. Furnaces in manufactured homes have to be listed for manufactured housing. A standard site-built furnace is not a drop-in swap.
- Ducts run under the floor. Look for crushed, disconnected or animal-damaged ducts in the crawl space. That is also where leaks and termites hide.
- Gas furnaces and water heaters need proper venting, combustion air and working carbon monoxide alarms.
- Coleman furnaces in manufactured homes have their own recall. See my York and Coleman guide.
More on these homes: what I found under an Apache Junction manufactured home.
Recalls to check
When I wrote this, I did not find a recent CPSC recall on Intertherm, Miller, Frigidaire or Maytag central air conditioners, heat pumps or furnaces. The only CPSC recall naming Nordyne was a 1996 recall of oil furnaces made by Ducane and sold under the Miller and Intertherm names, which are not used in Arizona. New recalls can come out at any time, so search your model number at cpsc.gov/Recalls.
What I check on the AC at an inspection
- Both data plates, outdoor and indoor, for age, size and refrigerant type. The two halves of a system are often different ages.
- The breaker size against the maximum listed on the data plate.
- How well it cools, measured as the temperature difference between the return and supply air.
- The condensate line, which should drain away from the home and not under it.
- The filter. See why a dirty AC filter matters in Arizona.
An older AC that works is a budget item, not a defect. Related: what a home warranty did with an old AC. When it is time to replace, check for rebates from SRP or APS, and verify the contractor with the Arizona Registrar of Contractors.
Other brands: Carrier, Bryant and Payne, Trane and American Standard, Lennox, Goodman, Amana and Daikin, Rheem and Ruud and York, Coleman and Luxaire.
Home inspections in Gilbert and across Arizona
At every home inspection I photograph the HVAC data plates, so the ages and model numbers are in your report. We inspect homes in Gilbert, Mesa, Chandler and across the Valley. See all of our service areas.
Buying a home? Book your inspection online or call 623-399-0079.