Carrier, Bryant and Payne air conditioners, heat pumps and furnaces come out of the same Carrier factories. The serial numbers read the same way, so one guide covers all three. Here is how to read the age, what each era means for a home in the Valley, and which recalls to check.
Who makes what
- Carrier. Named for Willis Carrier, who built the first modern air conditioner in 1902.
- Bryant and Payne. Both joined Carrier in 1955, when Carrier merged with Affiliated Gas Equipment, which owned Bryant, Payne and Day & Night. Carrier grouped them as “BDP” in 1974. Payne is the budget line with fewer models.
- Heil, Tempstar, Comfortmaker, Arcoaire and KeepRite. These International Comfort Products (ICP) brands are also part of Carrier today, but they use a different serial number system. One ICP recall is listed below.
Where to find the label
The outdoor unit’s data plate is usually on a side panel near the electrical connections. On a split system, the indoor unit (the air handler or furnace) has its own plate inside or on the cabinet. Check both. The outdoor unit is often replaced on its own, so the two parts of one system can be very different ages.
How to read the serial number
| Layout | Example | How to read it |
|---|---|---|
| Most units in service: four digits, a letter, five digits | 4006A17330 | First two digits are the week, next two are the year. Week 40 of 2006, which is early October. |
| BDP units, early 1980s | W4D14008 | A month letter and a single-digit year. These are rare today. |
| 1960s and 1970s | 46U152456 | Week, then a letter for the year: week 46 of 1967. |
Watch out: Lennox serial numbers look a lot like Carrier’s, but on a Lennox the first two digits are a factory code, not a week. Make sure of the brand before you decode. Sources: the Building Center’s Carrier decoder. Your Carrier dealer can also confirm the date and warranty from the serial number.
AC eras every Arizona buyer should know
These federal rules apply to every brand, so the build date tells you a lot about what is inside the unit.
| When | What changed | What it means for you |
|---|---|---|
| 1992 | First federal efficiency minimum: 10 SEER for split systems | A unit this old is long past its life in our heat. |
| January 23, 2006 | The minimum rose to 13 SEER. | Newer units use noticeably less power. |
| January 1, 2010 | New AC equipment could no longer be built to use R-22. | An R-22 unit was made before 2010. |
| January 1, 2015 | Split ACs installed in Arizona had to reach 14 SEER, plus an EER minimum for hot weather. | Arizona is in the Department of Energy’s Southwest region, with the toughest rules. |
| January 1, 2020 | R-22 production ended. | Recharging an R-22 system relies on recycled refrigerant and is expensive. Budget for replacement. |
| January 1, 2023 | A new test (SEER2). Southwest split ACs under 45,000 BTU must reach 14.3 SEER2 plus an EER2 minimum. | Labels from 2023 on show SEER2 numbers, which run a bit lower than the old SEER. |
| January 1, 2025 | New home systems can no longer be built for R-410A. Most now use R-454B or R-32. | R-410A units built before 2025 can still be installed and serviced. Ask what refrigerant a “new” unit uses. |
Sources: the Department of Energy’s central air conditioner standards FAQ and the EPA’s pages on the R-22 phaseout and refrigerant transition. Carrier’s own name for R-410A was Puron, so you will see that word on many Carrier labels.
Models you will see
| Carrier model starts with | What it is |
|---|---|
| 24 | Split system air conditioner (the outdoor unit) |
| 25 | Split system heat pump |
| 38 | Older split units and today’s ductless outdoor units |
| 48 | Gas/electric package unit (gas heat and AC in one cabinet, on the roof or the ground) |
| 50 | Package air conditioner or package heat pump |
| 58, 59 | Gas furnaces |
| FV4, FE4, FB4 | Fan coils (air handlers) for heat pump systems |
Bryant uses its own numbers (its Evolution Extreme heat pump is a 280ANV), and Payne models start with PA for air conditioners, PH for heat pumps and PG for furnaces. On all three, a three-digit number in the model gives the size in thousands of BTU: 036 is 36,000 BTU, or 3 tons.
Recalls to check
2017: Carrier Greenspeed and Bryant Evolution Extreme heat pumps (fire hazard)
- What: About 23,300 variable-speed heat pumps. Capacitors on the fuse board can stop working and let the unit overheat. Carrier had 41 reports of overheating.
- Models: Carrier 25VNA024, 25VNA036, 25VNA048 and 25VNA060; Bryant 280ANV024, 280ANV036, 280ANV048 and 280ANV060.
- Sold: June 2011 through August 2016.
- Fix: A free replacement fuse board installed by an authorized technician.
Details: CPSC recall 17-150.
Carrier and Bryant ductless heat pumps (fire hazard)
- What: About 5,350 ductless outdoor units whose fan motor can fail and overheat. Carrier had six reports of fires.
- Models: Carrier 38MGQC18—3, 38MGQF48—3 and 38MBQB48—3; Bryant 538TEQ018RCMA, 538TEQ048RFMA and 538REQ048RBMA.
- Sold: March 2015 through April 2019.
Details: CPSC recall notice.
2005: ICP gas-packs (fire hazard)
About 28,700 gas/electric package units sold as Airquest, Arcoaire, Comfortmaker, Heil, KeepRite, Kenmore, ICP Commercial and Tempstar had a control board that could ignite. Models start with PGC, PGF, PGS, GPFM, GPSM or GPCM, sold October 2000 through September 2005. Details: CPSC recall 06-011.
Through-the-wall units
Carrier, Bryant and Fast packaged terminal units (the through-the-wall kind used in hotels and some casitas) were recalled in 2007, 2015 and 2017 for overheating. Details: CPSC notice.
New recalls can come out at any time, so search your model number at cpsc.gov/Recalls.
What I check on the AC at an inspection
- Both data plates, outdoor and indoor, for age, size and refrigerant type.
- The breaker size against the maximum listed on the data plate.
- How well it cools, measured as the temperature difference between the return and supply air.
- The condensate line and pan, which can leak into ceilings in attic installs.
- The filter. See why a dirty AC filter matters in Arizona.
- Rooftop units and the roof around them. See what a rooftop AC did to an aging roof.
An older AC that works is a budget item, not a defect. Related: what a home warranty did with an old AC. When it is time to replace, check for rebates from SRP or APS, and verify the contractor with the Arizona Registrar of Contractors.
Other brands: Trane and American Standard, Lennox, Goodman, Amana and Daikin, Rheem and Ruud, York, Coleman and Luxaire and Intertherm, Frigidaire and Maytag.
Home inspections in Gilbert and across Arizona
At every home inspection I photograph the HVAC data plates, so the ages and model numbers are in your report. We inspect homes in Gilbert, Mesa, Chandler and across the Valley. See all of our service areas.
Buying a home? Book your inspection online or call 623-399-0079.