Lennox serial numbers trip people up because the first two digits are a factory code, not the date. Once you know that, a Lennox is easy to date. Here is how to read the label, what each era means for a home in the Valley, and which recalls to check.
Who makes what
- Lennox. Dates back to 1895 in Marshalltown, Iowa. Lennox sells its own brand directly to a network of independent dealers instead of through supply houses.
- Allied Air brands: Armstrong Air, AirEase, Concord, Ducane and Magic-Pak. Also made by Lennox International, but sold through distributors. Lennox bought Armstrong in 1988.
- Aire-Flo. Another Lennox brand sold to dealers.
Source: Lennox International’s annual report.
How to read the serial number
Look at the data plate on the outdoor unit and on the furnace or air handler. Many Lennox plates also print the manufacture date, which is the simplest answer.
| Years | Example | How to read it |
|---|---|---|
| 1973 on | 1606B13871 | 16 = factory. 06 = 2006. B = February. The last five digits are the unit’s sequence number. |
| Before 1973 | 724… | Year, then month: April 1972. |
Month letter (the fifth character): A January, B February, C March, D April, E May, F June, G July, H August, J September, K October, L November, M December. The letter I is skipped.
Don’t mix it up with Carrier. A Carrier serial such as 4006A17330 also has four digits and a letter, but there the first two digits are the week. On a Lennox they are always the factory. The 2020 Lennox recall below shows it: serials starting 6915 and 6916 are factory 69, built in 2015 and 2016. Source: the Building Center’s Lennox decoder.
Allied Air brands (Armstrong, AirEase, Concord, Ducane) have used their own formats over the years. On those, go by the date printed on the data plate or ask the brand’s support line with the serial number.
AC eras every Arizona buyer should know
These federal rules apply to every brand, so the build date tells you a lot about what is inside the unit.
| When | What changed | What it means for you |
|---|---|---|
| 1992 | First federal efficiency minimum: 10 SEER for split systems | A unit this old is long past its life in our heat. |
| January 23, 2006 | The minimum rose to 13 SEER. | Newer units use noticeably less power. |
| January 1, 2010 | New AC equipment could no longer be built to use R-22. | An R-22 unit was made before 2010. |
| January 1, 2015 | Split ACs installed in Arizona had to reach 14 SEER, plus an EER minimum for hot weather. | Arizona is in the Department of Energy’s Southwest region, with the toughest rules. |
| January 1, 2020 | R-22 production ended. | Recharging an R-22 system relies on recycled refrigerant and is expensive. Budget for replacement. |
| January 1, 2023 | A new test (SEER2). Southwest split ACs under 45,000 BTU must reach 14.3 SEER2 plus an EER2 minimum. | Labels from 2023 on show SEER2 numbers, which run a bit lower than the old SEER. |
| January 1, 2025 | New home systems can no longer be built for R-410A. Most now use R-454B or R-32. | R-410A units built before 2025 can still be installed and serviced. Ask what refrigerant a “new” unit uses. |
Sources: the Department of Energy’s central air conditioner standards FAQ and the EPA’s pages on the R-22 phaseout and refrigerant transition.
Models you will see
| Model starts with | What it is |
|---|---|
| XC, and older 10ACB, 13ACX, 14ACX | Split system air conditioner |
| XP, and older 13HPX, 14HPX | Split system heat pump |
| HS | Older condensing unit (the outdoor half of an AC) |
| SL, EL, ML | Gas furnaces |
| CBA, CBX | Air handlers and indoor coils |
| MPA and other M models | Ductless mini-split outdoor units |
The number after the dash is the size: XC16-036 is 36,000 BTU, or 3 tons. Lennox groups its lines as the Signature, Elite and Merit series, from top to entry level.
Recalls to check
2020: Ductless heat pump outdoor units (fire hazard)
- What: About 1,650 outdoor units in the U.S. that can overheat. Lennox had two reports, one with a fire.
- Models: MPA018S4M-1P, MPA048S4S-1P and MPA048S4M-1P, with serials starting 6915 or 6916.
- Sold: January 2016 through November 2019.
- Fix: Free replacement and removal of the outdoor unit. The indoor unit is not part of the recall.
Details: Lennox product recalls (CPSC recall 20-083).
Other Lennox recalls
The other Lennox recalls I found involved TUA series gas unit heaters for garages and shops (2011) and GWB8 gas boilers (2002). Neither shows up much in Arizona homes. Lennox’s split system air conditioners and heat pumps had no CPSC recalls in my search. New recalls can come out at any time, so search your model number at cpsc.gov/Recalls.
What I check on the AC at an inspection
- Both data plates, outdoor and indoor, for age, size and refrigerant type. The two halves of a system are often different ages.
- The breaker size against the maximum listed on the data plate.
- How well it cools, measured as the temperature difference between the return and supply air.
- The condensate line and pan, which can leak into ceilings in attic installs.
- The filter. See why a dirty AC filter matters in Arizona.
- Rooftop units and the roof around them. See what a rooftop AC did to an aging roof.
An older AC that works is a budget item, not a defect. Related: what a home warranty did with an old AC. When it is time to replace, check for rebates from SRP or APS, and verify the contractor with the Arizona Registrar of Contractors.
Other brands: Carrier, Bryant and Payne, Trane and American Standard, Goodman, Amana and Daikin, Rheem and Ruud, York, Coleman and Luxaire and Intertherm, Frigidaire and Maytag.
Home inspections in Gilbert and across Arizona
At every home inspection I photograph the HVAC data plates, so the ages and model numbers are in your report. We inspect homes in Gilbert, Mesa, Chandler and across the Valley. See all of our service areas.
Buying a home? Book your inspection online or call 623-399-0079.