How Old Is My Goodman, Amana or Daikin AC? Serial Numbers, Eras and Recalls

In this article

Goodman, Amana and Daikin units come from the same company and share one of the easiest serial numbers to read: year first, then month. Here is how to read it, what each era means, and which recalls to check.

Who makes what

  • Goodman. Based in Houston. Goodman bought Janitrol in 1982 and started building central air conditioners.
  • Amana. Goodman bought Amana’s parent in 1997. In 2002 it sold the appliance side to Maytag but kept the heating and cooling business, so Amana-brand AC units are Goodman products.
  • Daikin. The Japanese company Daikin bought Goodman in 2012. Daikin-brand ducted systems in U.S. homes are built alongside Goodman and Amana at the Houston campus.
  • Janitrol. An older brand you may still see on furnaces and package units.

Source: the Building Center’s Goodman page.

How to read the serial number

The data plate is on the side of the outdoor unit, and inside the door on furnaces and air handlers. Read the first four digits: the first two are the year and the next two are the month.

ExampleHow to read it
9704011000April 1997
1609…September 2016
2207…July 2022

The CPSC uses the same reading. In the 2017 furnace recall below, serials starting 1609 through 1612 match units sold from September 2016 through January 2017. A few through-the-wall units built for Goodman by Daikin used a different letter code, but you are unlikely to see those in a house.

AC eras every Arizona buyer should know

These federal rules apply to every brand, so the build date tells you a lot about what is inside the unit.

WhenWhat changedWhat it means for you
1992First federal efficiency minimum: 10 SEER for split systemsA unit this old is long past its life in our heat.
January 23, 2006The minimum rose to 13 SEER.Newer units use noticeably less power.
January 1, 2010New AC equipment could no longer be built to use R-22.An R-22 unit was made before 2010.
January 1, 2015Split ACs installed in Arizona had to reach 14 SEER, plus an EER minimum for hot weather.Arizona is in the Department of Energy’s Southwest region, with the toughest rules.
January 1, 2020R-22 production ended.Recharging an R-22 system relies on recycled refrigerant and is expensive. Budget for replacement.
January 1, 2023A new test (SEER2). Southwest split ACs under 45,000 BTU must reach 14.3 SEER2 plus an EER2 minimum.Labels from 2023 on show SEER2 numbers, which run a bit lower than the old SEER.
January 1, 2025New home systems can no longer be built for R-410A. Most now use R-454B or R-32.R-410A units built before 2025 can still be installed and serviced. Ask what refrigerant a “new” unit uses.

Sources: the Department of Energy’s central air conditioner standards FAQ and the EPA’s pages on the R-22 phaseout and refrigerant transition.

Models you will see

Model starts withWhat it is
GSX (Goodman), ASX (Amana), DX (Daikin)Split system air conditioner
GSZ (Goodman), ASZ (Amana), DZ (Daikin)Split system heat pump
GPGGas/electric package unit
GPC, GPHPackage air conditioner and package heat pump
GMS, GMV, GME (Goodman), AMEH (Amana), DM (Daikin)Gas furnaces
ARUF, ASPT, AWUF, ACNFAir handlers. AWUF mounts in a wall and ACNF in a ceiling, common in condos and apartments.
MBR, MBVCModular blowers that pair with an electric heat kit

The numbers after the letters give efficiency and size. A GSX140361 is a 14 SEER air conditioner, and the 036 means 36,000 BTU, or 3 tons.

Recalls to check

2017: Wall and ceiling air handlers (shock hazard)

  • What: About 210,000 Goodman AWUF and ACNF air handlers. The pull-out disconnect may not cut power, which puts anyone servicing the unit at risk of a shock.
  • Serials: Starting 1511, 1512, or 1601 through 1610. The label is behind the wall or ceiling panel.
  • Sold: November 2015 through October 2016, mostly in apartments and condos.
  • Fix: Free inspection and repair.

Details: CPSC recall 17-103.

2017: 80% gas furnaces (shock hazard)

About 4,100 furnaces with model numbers starting GME8 (Goodman), AMEH80 (Amana) or DM80HE (Daikin) and serials starting 1609 through 1612. The blower motor was not grounded. The fix is a free repair. Details: CPSC recall 17-145.

2018: Modular blowers (fire hazard)

About 1,650 Goodman, Amana, Daikin or unbranded modular blowers, models MBR1200AA, MBR1600AA, MBVC1600AA and MBVC2000AA, with serials starting 1704, 1705 or 1708, sold April through October 2017. The labels listed the wrong electrical information, which could lead an installer to use wire or breakers that are too small. Goodman provides a free inspection, a corrected label and, where needed, new wiring or breakers. Details: CPSC recall 18-115.

Through-the-wall units

Amana and Goodman packaged terminal units (the through-the-wall kind used in hotels, apartments and some casitas) were recalled in 2008, 2009 and 2014 for fire hazards, with serials in the 0701 to 0804 range.

New recalls can come out at any time, so search your model number at cpsc.gov/Recalls.

What I check on the AC at an inspection

  • Both data plates, outdoor and indoor, for age, size and refrigerant type. The two halves of a system are often different ages.
  • The breaker size against the maximum listed on the data plate.
  • How well it cools, measured as the temperature difference between the return and supply air.
  • The condensate line and pan, which can leak into ceilings in attic installs.
  • The filter. See why a dirty AC filter matters in Arizona.
  • Rooftop units and the roof around them. See what a rooftop AC did to an aging roof.

An older AC that works is a budget item, not a defect. Related: what a home warranty did with an old AC. When it is time to replace, check for rebates from SRP or APS, and verify the contractor with the Arizona Registrar of Contractors.

Other brands: Carrier, Bryant and Payne, Trane and American Standard, Lennox, Rheem and Ruud, York, Coleman and Luxaire and Intertherm, Frigidaire and Maytag.

Home inspections in Gilbert and across Arizona

At every home inspection I photograph the HVAC data plates, so the ages and model numbers are in your report. We inspect homes in Gilbert, Mesa, Chandler and across the Valley. See all of our service areas.

Buying a home? Book your inspection online or call 623-399-0079.

Buying a home in the Phoenix area?

Get a Certified Master Inspector on your side. Every home inspection includes a termite inspection at no extra charge, thermal imaging and a report within 24 hours.

Related articles