Rinnai is the tankless water heater I see most often in Valley homes, usually hanging on an outside wall or in the garage. It also builds tankless units sold under other names. Here is how to read the age, tell which generation you have, and check for recalls.
Who makes what
- Rinnai. A Japanese company founded in 1920. Rinnai America started in 1974, sold its first tankless water heater in North America in 1999, and is based in Peachtree City, Georgia. It added a U.S. plant in Griffin, Georgia in 2018.
- Bradford White and GE tankless. Rinnai began building tankless units for both brands in 2006.
- Giant tankless. Rinnai began building units for Giant in 2012.
Not every tankless unit is a Rinnai inside. The Rheem and Paloma power vent units in a 2007 recall came from Paloma, and Takagi units are now part of A. O. Smith.
How to read the serial number
The rating label is on the side of the unit. Rinnai has used three layouts.
| Layout | Example | How to read it |
|---|---|---|
| Since 2009: two letters | BL.CA-051306 | First letter is the year, second letter is the month. B = 2010, L = November. |
| Before 2009, with a period | 04.03-102521 | Year, then month: March 2004. |
| 1999 to 2008, digits only | 0508… | Year, then month: August 2005. |
| Year letter | Year | Year letter | Year |
|---|---|---|---|
| A | 2009 | M | 2020 |
| B | 2010 | N | 2021 |
| C | 2011 | O or P | 2022 |
| D | 2012 | R | 2023 |
| E | 2013 | S | 2024 |
| F | 2014 | T | 2025 |
| G | 2015 | W | 2026 |
| H | 2016 | X | 2027 |
| J | 2017 | Y | 2028 |
| K | 2018 | Z | 2029 |
| L | 2019 |
Month letter (second letter): A January, B February, C March, D April, E May, F June, G July, H August, J September, K October, L November, M December.
This table comes from the Building Center’s Rinnai decoder. If the date matters for a warranty, Rinnai’s support team can confirm it from the serial number.
Rinnai generations
Rinnai’s own service guide groups its tankless units by generation. This tells you a lot about a unit before you even read the serial number.
| Years | Generation | What it looks like on the label |
|---|---|---|
| 1999 to 2001 | First non-condensing units | Models 2402 (indoor) and 2424 (outdoor) |
| 2001 to 2006 | “V” series, 2nd generation non-condensing | Older R-models |
| 2006 to 2010 | “VA” series, 3rd generation | LS models, such as R94LSi and R94LSe |
| 2009 to 2010 | First condensing units | “KA” series |
| 2010 to 2011 | “VB” series, 4th generation | In 2011 the R94LS became the RL94, and the V53 became the RV53 |
| 2012 | “VC” series and the second condensing generation | Value series V65 and V75 arrive; condensing units become the RU98 and RU80 |
| Recent years | SENSEI condensing and RE non-condensing lines | RU, RUR, RUC, RUS and RX models (condensing); RE and REP (non-condensing) |
Generations come from Rinnai’s parts and service guide.
Reading a Rinnai model number
- The letters up front are the series. V is the basic Value series, RL the Luxury non-condensing series, RE and REP the current non-condensing line, and RU, RUR, RUC, RUS and RX are condensing (high efficiency, with PVC venting).
- The number is the size. On older models it roughly matches the gallons per minute (V75 is about 7.5). On newer ones it is the burner size in thousands of BTUs (RU199 is 199,000).
- i or e means indoor or exterior. An “e” unit on an outside wall in Arizona is normal.
- N or P means natural gas or propane. RL75iN is an indoor natural gas unit.
Recalls to check
When I wrote this, I did not find a CPSC recall on Rinnai tankless water heaters. Rinnai’s recall page lists two other products:
- 2025: i-Series Plus wall-mounted gas boilers (carbon monoxide). Models IP175S, IP199S, IP175199C and IP199199C sold September 2024 through February 2025. The boiler door can fail to seal because of incorrect screws. Details: CPSC recall 25-313.
- EnergySaver direct vent wall furnaces, models RHFE 431 and RHFE 556.
Neither is common in Arizona homes. New recalls can come out at any time, so search your model number at cpsc.gov/Recalls. Every gas appliance is one more reason to have working carbon monoxide alarms.
What I look for on a tankless unit
- Isolation valves. The service valves under the unit are how a plumber flushes out scale. Our hard water makes a yearly flush important, and units without valves rarely get one.
- Venting. Indoor units need the right vent pipe for their type. Condensing units also need a condensate drain.
- Error codes. A code on the display or the remote is worth writing down for the plumber.
- Gas line size. Tankless units need a lot of gas at once. An undersized line causes cold-water sandwiches and shutdowns.
A tankless unit usually lasts longer than a tank, often 15 to 20 years when it is flushed. Related reading: How Long Does a Water Heater Last in Arizona? Other brands: Navien, Noritz, Rheem, A. O. Smith and Takagi and Bradford White. Verify your plumber with the Arizona Registrar of Contractors.
Home inspections in Gilbert and across Arizona
At every home inspection I photograph the water heater’s data label, so the age and model number are in your report. We inspect homes in Gilbert, Mesa, Chandler and across the Valley. See all of our service areas.
Buying a home? Book your inspection online or call 623-399-0079.